24/7 monitoring  ·  Office Mon–Fri 8–5Service & Emergency  ·  Customer Service  ·  Pay Bill  ·  (770) 386-2846Text usText START to (470) 945-0080 for updates. Msg frequency varies. Msg & data rates may apply. Reply HELP for help, STOP to opt out.Text JOIN to (470) 790-5352 for offers. Up to 4 msgs/month. Msg frequency varies. Msg & data rates may apply. Reply HELP for help, STOP to opt out.
Owen Security Solutions CallText us

Fire alarm and inspections · Cartersville and metro Atlanta

Commercial fire alarm and NFPA 72 inspection guide

What NFPA 72 requires of a commercial fire alarm, how inspections are scheduled, and how Owen handles design, monitoring and repairs for Cartersville and metro Atlanta buildings.

Technician testing a ceiling smoke detector during a commercial fire alarm inspection

In short: Owen Security designs, installs, monitors and services commercial fire alarm systems and sprinkler monitoring across Georgia, and performs fire alarm inspection and testing to NFPA 72, along with sprinkler and extinguishing system inspections. Written reports go to you for the fire marshal and your insurer; deficiencies can be repaired by the same team. Call (770) 386-2846.

What NFPA 72 is, and who enforces it here

NFPA 72 is the National Fire Alarm and Signaling Code. It covers design, installation, monitoring and the inspection, testing and maintenance of fire alarm systems. Commercial fire alarm systems are also governed by the building and fire codes adopted in each state. NFPA 101 and the International Fire Code determine when a fire alarm is required.

In Georgia, the State Fire Marshal adopts NFPA codes by rule, and the local fire marshal acts as the Authority Having Jurisdiction (AHJ), approving plans and acceptance tests. Your AHJ and insurer may set additional requirements. Owen confirms the schedule for each building.

From design to acceptance testing

Owen's path for a new or replacement system is the same one described on the fire alarm page:

  1. Assessment. Occupancy, building size, sprinkler systems and existing equipment.
  2. Engineered design. Drawings are prepared by licensed engineers and submitted for permit with the local AHJ.
  3. Installation. Owen technicians install the panel, initiating devices, notification appliances and communicators. The team includes Level 2 Fire Alarm certification and Siemens fire alarm certification.
  4. Acceptance testing. The system is tested with the fire marshal for approval and occupancy.
  5. Monitoring and service. 24/7 supervising-station monitoring, plus inspection, testing and repair by the same team.

Nights, weekends and shutdowns are when a fire can grow unnoticed. Owen's monitoring center receives fire alarm, sprinkler supervisory and trouble signals around the clock and dispatches the fire department or your on-call contact, depending on the signal.

Monitoring, including cellular in place of phone lines

NFPA 72 Chapter 26 sets supervising-station monitoring requirements. Most commercial occupancies that are required to have a fire alarm must also have it monitored by an approved supervising station; your local fire marshal enforces that requirement.

Carriers are retiring the copper phone lines many older panels use. Recent editions of NFPA 72 allow a single cellular or IP communication path under defined conditions. Owen installs listed cellular and IP communicators, with local fire marshal approval, so monitoring stays supervised around the clock.

Supervisory signals report off-normal conditions such as a closed sprinkler valve. Trouble signals report faults such as a low battery. Both need prompt service.

Inspection frequencies

What is inspected, and how often

SystemFrequency
Fire alarm systems (NFPA 72, Ch. 14)Set per component: many annually, some semiannually, with visual inspections in between
Sprinkler systems (NFPA 25)Quarterly, annual and 5-year tasks
Portable extinguishers (NFPA 10)Monthly visual check by the owner, annual maintenance, hydrostatic testing at 5 or 12 years by type
Monitoring communicatorsTested with the fire alarm system

This schedule is the same one published on Owen's fire inspections page. The local AHJ and insurer may require more.

What you should get after an inspection

Inspection, testing and maintenance of fire alarm systems is governed by NFPA 72 Chapter 14, with records retained for review. Every Owen inspection ends with a written report that lists the building, the system, each device tested, the result and any deficiencies, with a recommended correction and a written quote. Systems are tagged, and records are retained for the next review.

Facility managers use the report to close out AHJ requirements, answer insurer loss-control requests and plan repairs in the budget cycle. Monitored, inspected systems are what insurers look for, often with lower insurance costs.

Owen also inspects systems it did not install, and can take over monitoring and service of an existing panel in most cases after an assessment.

Cartersville and metro Atlanta, served from Cartersville

Fire alarm and inspection work for Cartersville, Bartow County and metro Atlanta is served from Owen's main office at 10 W Main St, Cartersville, GA 30120. There is no separate Atlanta office. The same team that installs a system can inspect, monitor and repair it.

Related: commercial fire alarm systems · fire inspections · Cartersville location · metro Atlanta service area.

FAQ

Common questions

What is NFPA 72?

NFPA 72 is the National Fire Alarm and Signaling Code. It covers design, installation, monitoring and the inspection, testing and maintenance of fire alarm systems.

How often does a commercial fire alarm need to be inspected?

NFPA 72 sets inspection and testing frequencies by component. Most devices, including smoke detectors, pull stations, notification appliances and the control panel, are tested at least annually, and some components are visually inspected more often. Your local fire marshal (the authority having jurisdiction) can require more. Owen Security schedules inspections to the frequencies your building requires.

Who approves a commercial fire alarm system in Georgia?

The local Authority Having Jurisdiction, usually the fire marshal, reviews plans and witnesses acceptance testing before occupancy. In Georgia, the State Fire Marshal adopts NFPA codes by rule, and the local fire marshal acts as the AHJ.

Does my commercial fire alarm need to be monitored?

Most commercial occupancies that are required to have a fire alarm must also have it monitored by an approved supervising station; the requirement comes from the building and fire codes your local fire marshal enforces. Owen Security provides 24/7 fire alarm monitoring and can confirm your building's requirements during a site assessment.

Do you monitor sprinkler systems and inspect extinguishers too?

Yes. Owen monitors sprinkler waterflow (alarm), valve tamper (supervisory) and trouble signals 24/7. Fire alarm, sprinkler and extinguishing systems can be inspected, with sprinkler and extinguisher inspections scheduled alongside fire alarm work. Ask during your assessment which services apply to your building.

Can you fix deficiencies found during an inspection?

Yes. Owen services and repairs the systems it inspects and provides a written quote for any deficiency before work begins. Owen also inspects and services existing commercial fire alarm systems it did not originally install.

Can my fire alarm use cellular instead of phone lines?

Yes. Owen installs cellular fire alarm communicators that replace phone lines, in line with NFPA 72 and local fire marshal approval. Recent editions of NFPA 72 allow a single cellular or IP communication path under defined conditions.

Does Owen serve Cartersville and metro Atlanta?

Yes. Commercial fire alarm design, installation, monitoring and NFPA 72 inspections for Cartersville and metro Atlanta are served from Owen's main office at 10 W Main St, Cartersville, GA 30120. There is no separate Atlanta office. Call (770) 386-2846.

Schedule a fire alarm or inspection assessment

Schedule a complimentary site assessment with an Owen Protection Specialist. Call (770) 386-2846.