Fire Alarm & Sprinkler
Commercial fire alarm & sprinkler monitoring
Safeguard your building, inventory and people with code-compliant fire detection, installed, monitored, inspected and maintained by one provider and integrated with your entire security platform.

In short: Owen Security designs, installs, monitors and services commercial fire alarm systems and sprinkler monitoring across Georgia, with cellular alarm communication, 24/7/365 triple-redundant monitoring and NFPA 72 inspections from the same team. Call (770) 386-2846 for a complimentary site assessment.

One provider
We install, service and monitor fire alarms, sprinklers and extinguishers.
Cellular communication
No costly phone lines; faster, more secure alarm signals.
24/7/365 monitoring
Triple-redundant monitoring of alarm, supervisory and trouble signals.
Code knowledge
Design and installation specialists who know NFPA 72 and local fire codes and work with local fire inspectors.

After-hours protection
A panel can only warn the people who hear it.
Nights, weekends and shutdowns are when a fire grows unnoticed. Owen’s monitoring center receives fire alarm, sprinkler supervisory and trouble signals around the clock and dispatches the fire department or your on-call contact, depending on the signal, so a closed valve or a failed battery is fixed before it matters.
Who it’s for
Commercial fire alarm systems for occupied buildings.
Owen designs, installs, monitors and services commercial fire alarm systems for metro Atlanta businesses: office buildings and multi-tenant properties, industrial and manufacturing facilities, warehouses and distribution centers, retail, multifamily communities managed by property management firms, and new construction and tenant build-outs that need an approved system before occupancy.
- Facility managers and EHS leaders responsible for life-safety compliance
- Property managers with multi-tenant buildings and common areas
- General contractors and developers who need permit-ready fire alarm design
- Multi-site operators who want one fire and security partner
How it works
From engineered drawings to 24/7 supervision.
- Assessment. We review occupancy, building size, sprinkler systems and existing equipment.
- Engineered design. Drawings are prepared by licensed engineers and submitted for permit with the local AHJ.
- Installation. Owen technicians install the panel, initiating devices, notification appliances and communicators.
- Acceptance testing. We test the system with the fire marshal for approval and occupancy.
- Monitoring and service. 24/7 supervising-station monitoring, plus inspection, testing and repair by the same team.
Technology options
Components for every commercial occupancy.
| Option | Commercial use |
|---|---|
| Addressable control panels | Pinpointing the exact device in alarm or trouble |
| Smoke, heat and duct detectors | Offices, warehouses and HVAC systems |
| Horn/strobes and voice evacuation | Occupant notification, including mass notification |
| Sprinkler flow and tamper monitoring | Buildings with water-based suppression |
| Cellular and IP communicators | Replacing retired copper phone lines |
| Elevator recall and door release | High-rise and access-controlled buildings |
Owen technicians are certified on Siemens fire alarm systems.



Compliance
Built to NFPA 72 and approved by your AHJ.
Commercial fire alarm systems are governed by NFPA 72, the National Fire Alarm and Signaling Code, and by the building and fire codes adopted in each state. NFPA 101 and the International Fire Code determine when a fire alarm is required. In Georgia, the State Fire Marshal adopts NFPA codes by rule, and the local fire marshal acts as the Authority Having Jurisdiction (AHJ), approving plans and acceptance tests. NFPA 72 Chapter 26 sets supervising-station monitoring requirements, and recent editions allow a single cellular or IP communication path under defined conditions, which supports phone-line-to-cellular conversions.
Industries
Where Owen fire alarms protect commercial property.
- Office and multi-tenant: Code-compliant detection and notification for every suite
- Industrial and manufacturing: Harsh-environment detection and sprinkler monitoring
- Warehouses and distribution: Large open spaces, high-piled storage and flow monitoring
- Multifamily and property management: Common-area systems and monitored sprinklers
- Construction: Permit-ready design for new buildings and build-outs
- Retail and restaurants: Detection, notification and duct detectors
Integration
Fire and security from the same team.
Every Owen system is designed to work with the others, so one team owns the result and one partner answers the phone.
- Fire inspections: the team that installed it inspects and repairs it
- Access control: doors release on alarm where required
- Intrusion alarms: one monitoring account and call list
- Video surveillance: visual context for every event
Phone lines to cellular
Copper lines are going away. Your fire alarm can’t.
Carriers are retiring the copper phone lines many older fire alarm panels use to reach the monitoring center. Owen replaces them with listed cellular and IP communicators that send signals faster and are supervised around the clock, keeping your building compliant and your monitoring uninterrupted.
Utilities and critical infrastructure
Fire detection for control buildings and treatment plants.
Utility control buildings, operations centers, warehouses and water and wastewater plants need fire detection that reports reliably from remote locations. Owen designs NFPA 72 systems with supervised cellular or IP communication and coordinates with the local AHJ.
Your Integrated Protector · One-sheet
See the whole system on one page.
Security, fire protection, access control and AI Smart Video Monitoring combined into one proactive system, from one trusted partner for over 50 years, often with lower insurance costs.
How we work
From site assessment to 24/7 proactive monitoring
- 01
Site assessment
A complimentary walkthrough of your property, risks, existing equipment and network.
- 02
System design
A written proposal engineered around your facility, your operations and your budget.
- 03
Installation
Certified Owen technicians and project coordinators manage the install from start to finish.
- 04
Monitoring & service
24/7/365 triple-redundant monitoring and a local service team that knows your system.
FAQ
Common questions
Does my commercial fire alarm need to be monitored?
Most commercial occupancies that are required to have a fire alarm must also have it monitored by an approved supervising station; the requirement comes from the building and fire codes your local fire marshal enforces. Owen Security provides 24/7 fire alarm monitoring and can confirm your building’s requirements during a site assessment.
Do you monitor sprinkler systems?
Yes. Owen monitors sprinkler waterflow (alarm), valve tamper (supervisory) and trouble signals 24/7 and dispatches according to the signal type.
Can my fire alarm use cellular instead of phone lines?
Yes. Owen installs cellular fire alarm communicators that replace phone lines, in line with NFPA 72 and local fire marshal approval.
Which fire systems are your technicians certified on?
Our team includes Level 2 Fire Alarm certification and Siemens fire alarm certification.
Do you install fire alarms for utility and treatment-plant buildings?
Yes. Owen designs and installs fire alarm systems for control buildings, operations centers and water and wastewater facilities, with supervised communication for remote sites.
Who approves a commercial fire alarm system?
The local Authority Having Jurisdiction, usually the fire marshal, reviews plans and witnesses acceptance testing before occupancy.
Do you provide engineered fire alarm drawings?
Yes. Owen coordinates engineered drawings and permit submittals for new systems and build-outs.
Can you take over an existing fire alarm system?
In most cases, yes. Owen assesses the existing panel and devices, then provides monitoring, inspection and service.
What is a supervisory or trouble signal?
Supervisory signals report off-normal conditions such as a closed sprinkler valve, and trouble signals report faults such as a low battery. Both need prompt service.
Does Owen install fire alarms for new construction?
Yes. Owen works with general contractors and developers from design and permit through acceptance testing.
Integrated solutions
One partner for every system
Ready to protect your facility?
Schedule a complimentary site assessment with an Owen Protection Specialist.
